1. Explosion-proof mark: Exd [ib] ⅡCT6
2. Working voltage: DC24V
3. The maximum open circuit voltage: U0
<27V
4. The maximum short circuit current: I0≤
100mA
5.Working Environment:
Temperature: -20 ℃ ~ + 50 ℃
Relative humidity: ≤95% non-condensing
Atmospheric pressure: 80kPa ~ 110kPa
1, According to the site with the M6 screws
through the mounting foot barrier barrier
explosion-proof housing is fixed to the
ceiling or wall. Introducing means using
the cable clamping nut seal ring structure.
2, Wiring methods: Loosen the screws
explosion-proof enclosure, open the
explosion-proof chamber, the cable
connected to the terminal on the barrier
(see below). Wires connected, the
explosion-proof safety barrier cover
installed.
Input for the power supply; intrinsically
safe power supply output terminal