INPUT | ||||||
Nominal Voltage | 220/230/240Vac(L+N+PE) | |||||
Operating Voltage Range | 120~276Vac | |||||
Frequency Range | 45~55Hz/54~66Hz±0.5Hz | |||||
Power Factor | ≥0.99 | |||||
Bypass voltage range | 220V: +25%(optional +10%,+15%,+20% ) Bypass voltage range 230: +20% (optional +10%,+15%) 240: +15% (optional +10%) Min. voltage: -45% (optional -20%,-30%) | |||||
Bypass frequency range | Frequency protection range:±10% | |||||
ECO range | Same as the bypass | |||||
Harmonic distortion (THDi) | <3%(100% linear load) | |||||
Generator input | Support | |||||
OUTPUT | ||||||
Output Voltage | 220/230/240Vac | |||||
Power Factor | 0.9 | |||||
Voltage Regulation | ±2% | |||||
Frequency | Line Mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency(optional) | ||||
Bat. Mode | 50/60(±0.1)Hz | |||||
Crest Factor | 3:1 | |||||
Harmonic Distortion (THDv) | ≤2% with linear load | |||||
≤5% with non-linear load | ||||||
Efficiency | >93.5% | |||||
BATTERY | ||||||
Battery voltage | Optional Voltage: ±96/±108/±120Vdc | |||||
Typical recharging time | 6~8 hours (to 90% of full capacity) | |||||
Backup time | Long run unit depends on the capacity of external batteries Estimated remaining time displayed on the LCD | |||||
Charging current | Maximum current 10A; Charging current can be set according to battery capacity installed. | |||||
SYSTEM FEATURES | ||||||
Transfer time | Utility to battery : 0ms; Utility to bypass: 0ms | |||||
Overload | Line Mode | Load≤110%: last 60min; ≤125%: last 10min; ≤150%: last 1S;>150% turn to bypass mode | ||||
Bypass Mode | 40A(Breaker) | 60A(Breaker) | ||||
Short circuit | Hold whole system | |||||
Overheat | Line Mode: Turn to Bypass; Bat. Mode: Shut down UPS immediately | |||||
Battery low | Alarm and switch off | |||||
Self-diagnostics | Upon power on and software control | |||||
EPO (optional) | Shut down UPS immediately | |||||
Battery | Advanced battery management | |||||
Noise suppression | Complies with EN62040-2 | |||||
Audible & Visual alarms | Line failure, Battery low, Overload, System fault | |||||
Status LED & LCD display | Line mode, Backup mode, Eco mode, Bypass mode, Battery under voltage, Battery bad, Overload & UPS fault | |||||
Reading on the LCD display | Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature & Remaining battery backup time | |||||
Communication interface | USB,RS232,Parallel port, SNMP card/Relay card (optional) | |||||
ENVIRONMENT | ||||||
Operating temperature | 0℃~40℃ | |||||
Storage temperature | -25℃~55℃ | |||||
Humidity range | 0~95% (non-condensing) | |||||
Altitude | < 1500m | |||||
Noise level | <55dB | |||||
PHYSICAL | ||||||
Dimension W×H×D (mm) | 443×131×580(3U) | |||||
Net weight (kg) | 23 | 25 | ||||
STANDARDS | ||||||
Safety | IEC/EN62040-1,IEC/EN60950-1 | |||||
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4, IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 |